Tyler Bus Hooks Service cannot be reached after upgrading it to v2021.1.18
Time and Attendance shows the message Workflow Services are not currently available.Â
When testing the Tyler Workflow connection, the error messages are:
   Tyler Workflow reports partial required components available
   Tyler Bus Hooks Service cannot be reached
When browsing to the Tyler Bushooks dashboard, the following error is received:
   HTTP Error 500.31 - ANCM Failed to Find Native Dependencies
Time and Attendance Application log shows the following error:
   Error creating or sending REST request to https://FQDN/instance/tylerbushooks/api/Status 500 Internal Server Error
Time and Attendance
ExecuTime
Tyler Workflow
TWF
Tyler Bushooks
Bushooks
Bushooks v2021.1.18
This is caused by not having the required .NET Core 8.0 Runtime Hosting Bundle installed on the Tyler Workflow server
*Note: All error messages described in the Description of Issue must be present for this resolution to apply
On the Tyler Workflow Server, open a browser and navigate to https://dotnet.microsoft.com/en-us/download/dotnet/8.0Â
Under the latest release, select the Windows Hosting Bundle for ASP.NET Core Runtime 8.0.XX
Let the download start and complete
Select the file from the browser downloads to start the installation
Select the check box for I agree to the license terms and conditions
On the pop up, select Yes
Installation will take place and once completed, it will show Installation Successfully Completed
Select Close
Reboot the server
Login to Time and Attendance and test the Tyler Workflow connection to ensure that the Bushooks error is resolved
After the server is rebooted, logging immediately into the application and testing the connection might still show Tyler Workflow reports partial required components available message.
This is normal as the services have not stood up as quickly as Time and Attendance and testing the connection again will show a successful connection