Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

...

...

...

...

...

...

...

...

...

...

...


Panel
borderColor#03396c
titleColorWhite
titleBGColor#03396c
titleDescription of Issue

How do I install the Honeywell Xenon 1950 handheld scanner to work with Cashiering?

...

Panel
borderColor#03396c
titleColorWhite
titleBGColor#03396c
titleContext
  • Honeywell Scanner
  • Cashiering 2019.1+
  • Honeywell 1900
  • Honeywell 1950
  • Honeywell 1960
  • Handheld scanner
  • Scan line


Panel
borderColor#03396c
titleColorWhite
titleBGColor#03396c
titleCause

This article covers the installation process for the Honeywell Scanner for Cashiering 2019.1+

...

UNKNOWN_ATTACHMENT
  1. Image Added
  2. Scan the
barcode
  1. QR code below to configure the scanner for
Cashiering and  Ports
  1. Cashiering and to put it in COM port emulation mode
  2. Image Modified

Open Windows Device Manager 

Expand
  1. Once the QR code has been scanned, in Device Manager the scanner will show under Ports (COM & LPT) as USB Serial Device (COMX)
  2. Expand Ports (COM & LPT) and note the number of the COM port that the scanner was created on as
this
  1. this will be required to setup the scanner in the Cashiering Hardware Console. If you are unsure which port is being used, you can unplug the scanner, observe which one disappears, then plug it in again and observe which one appears.

Configure with Cashiering

  1. Open the Cashiering Hardware Console
    1. Click the Pencil icon
    2. Add the scanner and set the COM port to reflect what you see in Device Manager
    3. Click Save
    4. Close Hardware Console from browser and system tray, then restart Hardware Console before testing:
 
    1. How to Restart Cashiering Hardware Console
  1. Setup and test in Cashiering
    1. In Cashiering, navigate to Administration Payment Types
    2. Locate applicable payment type and click
the 
    1. the Pencil icon to edit
    2. Click
the 
    1. the Scanning tab
    2. Click into Test Scan field
    3. Scan applicable item
Panel
borderColor#03396c
titleColorWhite
titleBGColor#03396c
titleResolution

Driver Installation

  1. Download theCashiering Hardware Drivers
installation
  1.  installation package from Tyler Community
at 
  1. at https://tylercommunity.tylertech.com/cashiering/m/downloads/35856
  2. Navigate to the download location and unzip/extract all files from TylerCashiering.DeviceDriversInstaller.2020.2.0.1.zip
  3. Navigate toTylerCashiering.DeviceDriversInstaller.2020.2.0.1\ManualHardwareDriversV3\Xenon1900\HSM USB Serial Driver ver 3.1.4
  4. Right-click
on 
  1. on setup.bat
 and choose 
  1.  > choose Run as administrator
    1. On the Welcome screen, click Next
    2. The default installation path
is 
    1. is C:\Program Files\Honeywell\Honeywell HSM Serial Driver x64 version 3.1.4
    2. Install driver
for 
    1. for Everyone
Click 
    1. Click Next through the remaining screens until installation is complete
  1. Once the install is done, connect the scanner to the PC and wait for Windows to detect and install the 19xx scanner

Device Programming

  1. Open Windows Device Manager
  2. After connecting the scanner but before scanning the QR code, in Device Manager the scanner will show under POS Barcode Scanner as POS HID Barcode scanner. This is normal at this point, but the QR code below must be used to switch it to COM port use to work correctly with the Cashiering Hardware Console.
  3. It's a good idea to reset the scanner back to its defaults before adding further programming for use with Tyler apps. To reset to defaults, first scan the top Remove Custom Defaults bar code, then scan the Activate Defaults bar code.
View file
name


Panel
borderColor#03396c
titleColorWhite
titleBGColor#03396c
titleAdditional Information
  • You must have administrator rights to install drivers
  • If you intend to use the scanner for OCR, you must have a license for it. On some models, the license is an additional cost.
See  for
  •  for further information.
  • OCR-A and OCR-B is supported. OCR-A tends to be easier to read. You can find the OCR-A font in Microsoft Word to create test strings if you wish. No need to print first – you can scan them on the screen.


The QR code provided above sets the following settings:

  • USB COM port emulation: CDC ACM (default is USB PC keyboard)
  • Beeper volume setting: Low (default is High)
  • OCR Template Selection: User and Internal MICR E-138 Templates (default is User Template Only)
  • OCR: OCR On – Normal Video (default is OCR Off)
  • OCR Template: 135E320 (default is 13777777770). This setting specifies both OCR-A and OCR-B, only Numeric values, 32 characters.
  • Suffix Command Value: 990D0A (default is NULL)


Additional Options

Presentation Mode

Scan the Presentation Mode barcode below if the scanner will be in a stand, or any other situation where it should always be on.

Image Removed

Image Added


39 Character OCR Scanning

 –

 (Munis bills): If needed, the scanner can be configured for 39 numeric character scanning instead of 32 using this QR. This QR makes only the following modification:

OCR Template: 135E390 (OCR-A & OCR-B, Numeric only, 39 characters)

Image Removed

Image Added


41 Character OCR Scanning

 –

 alpha-numeric string and spaces (spaces count toward 41 character limit). Does not read more than one consecutive space - (Special Use), This QR makes only the following modification:

OCR Template: 138E410 (OCR-A & OCR-B, any type of character, including spaces, 41 characters)

Image Removed

Image Added


44 Character OCR Scanning

 –

 alpha-numeric string with no spaces. This QR makes only the following modification:

OCR Template: 137E440 (OCR-A & OCR-B, Alpha and Numeric characters, no spaces, 44 characters)

Image Removed

Image Added


Additional Resources

the  and
  •  and navigate to Software > Barcode Scanners >  Software > Tools and Utilities > EZConfig for Scanning > Current    This software is needed to generate QR codes like the above to program the scanner in the event a custom setup is required.