Description of Issue
Genus 1 clock is displaying ExecuTimeCMApp error
Context
- ExecuTime
- ET
- Genus 1
- G1
Cause
Clock needs firmware pushed
Resolution
- On ExecuTime server, navigate to EXECUTIMEDRIVE:/EXECUTIMEFOLDER/System/ClockPolling
- Open the tftpd64.400.zip file
- Run the tftpd64.exe
- In TFTP, navigate to the Tftp Client tab
- For host, enter the device's IP address
- for Local File, select the ... button
- Direct to the G1v file located at EXECUTIMEDRIVE:/EXECUTIMEFOLDER/System/ClockPolling/Firmware. The file may be in a folder named Genus1 or G1.
- For Remote File, enter \flashdisk\Genus
- Select Put
- Wait for the device to reboot
- In TFTP, for Local File, select the ... button
- Direct to the Classes file located at EXECUTIMEDRIVE:/EXECUTIMEFOLDER/System/ClockPolling/Firmware
- For Remote File, enter \flashdisk\Classes.jar
- Select Put
- Wait for the device to reboot
Additional Information
If firmware files are not present, contact ExecuTime Support.