Description of Issue

Receiving a validation error when uploading TEST file to the reporting agency.

"Country" attribute (481 ) is not a valid Country.

Context
  • Payroll
  • New Hampshire
  • NHRS Report
Cause

Submission file create adds a space after the 3 digit code. 

Resolution

Install (master) work ticket MUN-463151 when available. 

Work around: 

  • If Country should be USA (481), remove the Crosswalk column value.
  • If Country should be Mexico (335) or Canada (107), remove the space from the submission file for affected employees. 
Additional Information

Master Article - NHRS Report submission validation error

NHRS Report Setup

The Country code will default to 481 unless the value in the Country field of the Employee Master is crosswalked to something else in Crosswalk Type RSCNTRY.