Description of Issue
  • When selecting default settings in VSS Vendor Administration the screen opens to a server error 500
  • VSS Exception Logging: 

    MUNIS Web Services -- Calling apwsvssh_get_type
    URL - https://<hostname>/prod/munis/gas/svcMSS/ws/r/mugws/apwshdlr
    Parameters in - <param get_types="" />

    MUNIS Web Services -- Called apwsvssh_get_type
    Return code - 0
    XML out -

    ]]></Trace>
    <Stack><![CDATA[ at System.Xml.XmlTextReaderImpl.Throw(Exception e)

Context
  • Vendor Administration
  • Vendor Type Codes
  • Vendor Self Service (VSS)
  • Accounts Payable Miscellaneous Codes
Cause

Munis Web services returns no value when calling apwsvssh_get_type as no Vendor Type Codes exist

Resolution
  1. Verify in Munis that Vendor Type Codes have been setup under Financials→ Accounts Payable→ Setup→ Accounts Payable Miscellaneous Codes
    1. If no Vendor Type Codes are found listed use the following article for setup: How to add a vendor type code
  2. Once the necessary codes have been added to Munis the VSS Default Settings page will resolve properly